PSF-L Series -
Texio Technology Corp.
* Flexible output range Possible to output voltage and current flexibly within the rating power. In case of PSF-800L, 10V/80A to 80V/10A, 20V/40A to 40V/20A, etc. are available corresponding to plural number of conventional regulated DC power supplies.* 90rotating panel operation part 90rotating panel installs the unit vertically or horizontally.* Sequence f
-
HEM -
TOEI INDUSTRY CO, LTD.
The physical quantity of Hall Coefficient, Hall Mobility and Carrier Density etc. can be investigated by measuring at room temperature voltage occurred perpendicularly to the both magnetic field and constant-current when flowing constant-current perpendicularly to magnetic field from current source while applying magnetic field to sample set at the center of magnetic field of magnet.
-
Model 50/12 -
TREK, INC.
The Model 50/12 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slew rate, wide bandwidth, and low-noise operation. It is designed to provide precise control of output voltages in the range of 0 to ±50 kV DC or peak AC with an output current range of 0 to ±12 mA DC or peak AC.
-
HH2102A -
Colluck Company Limited
Basic Accuracy 1.0%. Jumbo LCD display 2000 count, 21mm figure height. Manual Ranging at your choice (19 Range). Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ. Signal injection and Diode test
-
HH2202 -
Colluck Company Limited
High Accuracy (Basic Accuracy 1.0%). Jumbo LCD display 4000 count, 21mm figure height. Convenient Auto Ranging. Higher Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 40MΩ. Diode test, audible continuity check
-
AMETEK Sensors, Test & Calibration
Our multifunction process calibrators read and source RTD, thermocouple, current, voltage, frequency, and resistance to calibrate or verify your process sensors. They can also be combined with APM CPF pressure modules to calibrate pressure, or a dry-block to calibrate temperature. The ASC-400 features a large full color display with an advanced simplicity, easy-to-use interface.
-
8012e -
Sealevel Systems, Inc.
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
CSN Series -
Chuan Sheng Electronics Co., Ltd.
CSN Series 3 1/2 Digital Process Meter is a simple type of economic Panel Meter, and its large LED display with 20.0mm and anti-jamming design, quality, reliable, easy to install.Full range can be specified DC voltage / current, thermal resistance , load cell, potentiometer , Resistance and pulse signals such as the general measurement requirements.
-
UI9600 -
Lisun Electronics Inc.
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
40-614C-006 -
Pickering Interfaces Ltd.
This 4-bank, 32-channel, 1 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-017 -
Pickering Interfaces Ltd.
This 1-bank, 32-channel, 4 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-009 -
Pickering Interfaces Ltd.
This 4-bank, 4-channel, 8 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-002 -
Pickering Interfaces Ltd.
This 16-bank, 4-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614C-003 -
Pickering Interfaces Ltd.
This 8-bank, 16-channel, 1 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
CM1000 -
General Technologies Corp.
Clamp opens up to 1 inch (25.4 mm). One rotary switch operation. Large 4 digit LCD display. AC/DC Voltage measurement up to 1000 Volt. AC/DC current measurement up to 1000 A. Relative measurement. One touch auto zero. Peak Hold Function. Data Hold Function